Refine Your Search

Topic

Search Results

Standard

400 Hz Connection Aircraft Electrical Maintenance Procedures

2008-03-28
HISTORICAL
AIR4365A
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

400 Hz CONNECTION AIRCRAFT ELECTRICAL MAINTENANCE PROCEDURES

1994-12-01
HISTORICAL
AIR4365
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

Method of Evaluating Pneumatic Ground Power Units

2003-11-21
HISTORICAL
AIR4545
This SAE Aerospace Information Report (AIR) covers, and is restricted to, the behavior of air under conditions of critical and subcritical flow at temperatures less than 500 °F.
Standard

Fuels in Ground Support Equipment (Other Than Gasoline or Diesel)

1999-01-01
HISTORICAL
AIR5373
This SAE Aerospace Information Report (AIR) is intended as a source of comparative information and is subject to change to keep pace with experience and technical advances. This document describes currently used fuels and fuels which may be used in the future. Conventional gasoline and diesel fuels are intentionally omitted from this document.
Standard

Fuels in Ground Support Equipment (Other Than Gasoline or Diesel)

2020-09-23
CURRENT
AIR5373A
This SAE Aerospace Information Report (AIR) is intended as a source of comparative information and is subject to change to keep pace with experience and technical advances. This document describes currently used fuels and fuels which may be used in the future. Conventional gasoline and diesel fuels are intentionally omitted from this document.
Standard

Design Factors - Handicapped Passenger Boarding Devices

2002-07-16
HISTORICAL
AIR4652
This SAE Aerospace Information Report (AIR) covers handicapped passenger boarding devices used airside to transfer handicapped passengers between the terminal building and the aircraft. It provides an elevating platform to facilitate access to the aircraft; it does not cover devices for in-terminal or streetside transfers, wheelchairs for on-board aircraft or in-terminal usage, or aircraft boarding bridges. However, it should be recognized that for many handicapped passengers, a boarding chair is necessary for the lifting operation and movement to the passenger's seat inside the aircraft cabin. Such wheelchairs are widely used in larger aircraft, and the Federal Aviation Agency has developed a performance specification for a boarding chair for commuter aircraft.
Standard

Design Factors - Handicapped Passenger Boarding Devices

2014-03-11
CURRENT
AIR4652A
This SAE Aerospace Information Report (AIR) covers handicapped passenger boarding devices used airside to transfer handicapped passengers between the terminal building and the aircraft. It provides an elevating platform to facilitate access to the aircraft; it does not cover devices for in-terminal or streetside transfers, wheelchairs for on-board aircraft or in-terminal usage, or aircraft boarding bridges. However, it should be recognized that for many handicapped passengers, a boarding chair is necessary for the lifting operation and movement to the passenger's seat inside the aircraft cabin. Such wheelchairs are widely used in larger aircraft, and the Federal Aviation Agency has developed a performance specification for a boarding chair for commuter aircraft.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1991-05-01
HISTORICAL
ARP1148A
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

Ground Electrical Power Unit, Transportable 115/200 Volt AC (Nominal) 400 Hertz, 3-Phase 4-Wire (Grounded Neutral) Y-Connected System

2013-10-22
CURRENT
ARP1148B
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1970-02-01
HISTORICAL
ARP1148
This Recommended Practice outlines the general requirements for a transportable self-contained, continuous duty, diesel engine driven brushless alternator unit for supplying 400-Hertz electrical power to high performance commercial transport aircraft. It is intended to assist the airlines in standardardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications by the purchaser. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations at airports throughout the world. The combination of the equipment specified herein and the interconnecting cable(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704A requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

Chassis Mounted Lifts Used to Board Airline Passengers With Mobility Impairments

1999-07-01
HISTORICAL
ARP5141
This SAE Aerospace Recommended Practice (ARP) is intended to recommend a minimum standard, for the design and manufacturer of a self-propelled, chassis mounted passenger boarding vehicle. The vehicle will permit safe operation while minimizing aircraft damage and personnel safety hazards associated with commercial aircraft boarding operations. The vehicle described is intended to be used for assisting wheelchair passengers and passengers with disabilities on and off aircraft with door sill heights of 60 in (152.4 cm) and above.
Standard

Chassis Mounted Lifts Used to Board Airline Passengers With Mobility Impairments

2014-03-11
CURRENT
ARP5141A
This SAE Aerospace Recommended Practice (ARP) is intended to recommend a minimum standard, for the design and manufacturer of a self-propelled, chassis mounted passenger boarding vehicle. The vehicle will permit safe operation while minimizing aircraft damage and personnel safety hazards associated with commercial aircraft boarding operations. The vehicle described is intended to be used for assisting wheelchair passengers and passengers with disabilities on and off aircraft with door sill heights of 60 in (152.4 cm) and above.
Standard

EXHAUST EMISSION LIMITS FOR DIESEL ENGINES USED IN AIRCRAFT GROUND SUPPORT EQUIPMENT AT AIRPORT ENVIRONMENTS

2002-12-16
CURRENT
AIR1312
This Aerospace Information Report (AIR) outlines the conditions which diesel engines should meet when installed and used as prime movers for aircraft ground support equipment at commercial airports. All aircraft ground support equipment with a heavy duty diesel engine as defined on page 24293 of the November 15, 1972 Federal Register and used as a prime mover for the vehicle or equipment should meet all requirements as outlined herein. Typical equipment includes fuel trucks, commissary trucks, baggage tractors, ground power units, air start units, etc.
Standard

Ground Support Equipment Hydraulic Systems, Design and Installation, Recommended Practices for

2022-12-16
CURRENT
ARP4943A
This SAE Aerospace Recommended Practice (ARP) covers the design and installation requirements for hydraulic systems (up to 8000 psig [56 MPa]) for ground support equipment (GSE). This ARP is derived from AS5440, which provides hydraulic system requirements for aircraft. The recommendations herein are primarily intended for GSE that exchange hydraulic fluid with the aircraft, such as hydraulic service carts, rather than GSE with non-interfacing hydraulic systems. The GSE may be mobile, portable, or stationary.